ABD Composites

Bolted joint, bonded joint and open-hole verification

Bonded joint, bolted joint and open-hole results compared with lab tests, finite element models and published predictions.

Maintained by Rick Schrijver ·
Showing 30 of 30 cases
Area: Joints and Open Holes

How close the results are

Lab tests show how close a prediction comes to a measured part. Reference solutions show that the program solves its equations the way someone else solved the same problem. A case is one configuration checked against one source, and it scores by its value with the largest error. A lab case that runs every failure criterion or every micromechanics model scores by Puck (the Puck failure criterion or the Puck micromechanics model), the same choice for all of them. The other models show in its row. Fitted cases show in their source but stay out of every number.

Lab tests: strength

Validation: failure loads of coupons, tubes, beams and joints, compared with published test programs. Where the app has several failure criteria, a case scores by Puck. The other criteria show in its row.

Cases
8 cases from 1 source, 8 compared numbers
Within 10 %
6 of 8
Median error
3.76 %, known gaps left out
Bias and scatter
+2.60 % on average, ±5.05 % scatter (1 SD)
Known gaps
2, see the list

Published solutions

Verification: the same inputs run against worked examples, tables and closed-form answers printed in textbooks, NASA reports and journal papers.

Cases
2 cases from 1 source, 2 compared numbers
Within 1 %
2 of 2
Median error
0.0099 %
Largest error
0.017 %
Known gaps
None

Finite element models

Verification: a plane-stress finite element model of the same problem, solved in an open-source code. Each model runs on two meshes.

Cases
16 cases from 1 source, 68 compared numbers
Within 1 %
14 of 16
Median error
0.13 %
Largest error
3.46 %
Known gaps
None

ABD Composites runs no tests of its own. Each measured value comes from a published test program.

Sources

Each row is one source the results are checked against. Error is the difference between the program's value and the source's value, as a percentage of the source's value. A reference case passes at 1 % or less, a lab case at 10 % or less. Open a row to see every case, its chart and how to reproduce each number.

SourceTypeCasesMedian errorLargest error ↓
Lab testsValidation: predictions against measured parts. Limit 10 %.
Reference solutionsVerification: the same model solved by someone else. Limit 1 %.

The tick on each bar marks the limit for that group. A bar past the tick is over the limit.

How the numbers are checked

The two groups answer two different questions. Reference solutions check that the program solves its equations correctly: the same model, solved by someone else in a published solution, an independent implementation or a finite element model, gives the same number. Engineers call this verification. Lab tests check that the equations describe a real part, which no amount of matching other programs can show. That is validation. A method can pass every verification case and still differ from a test, because the model leaves something out. The terms follow NAFEMS, What is Verification and Validation? (2014).

A reference case counts as within when its error is at most 1 %, a lab case when it is at most 10 %. A known gap is a case where the method and the reference disagree for a reason that is understood. It stays on this page with its reason until the method changes.

Back to every area

Ask AI