- Verification
- /
- Tubes
Composite tube stiffness and buckling against lab tests
Tube stiffness and buckling loads compared with results measured in published test programs.
How close the results are
Lab tests show how close a prediction comes to a measured part. Reference solutions show that the program solves its equations the way someone else solved the same problem. A case is one configuration checked against one source, and it scores by its value with the largest error. A lab case that runs every failure criterion or every micromechanics model scores by Puck (the Puck failure criterion or the Puck micromechanics model), the same choice for all of them. The other models show in its row. Fitted cases show in their source but stay out of every number.
Lab tests: strength
Validation: failure loads of coupons, tubes, beams and joints, compared with published test programs. Where the app has several failure criteria, a case scores by Puck. The other criteria show in its row.
No lab test of this kind is published for tubes yet.
Published solutions
Verification: the same inputs run against worked examples, tables and closed-form answers printed in textbooks, NASA reports and journal papers.
No published solution is listed for tubes yet.
Finite element models
Verification: a plane-stress finite element model of the same problem, solved in an open-source code. Each model runs on two meshes.
No finite element model is listed for tubes yet.
ABD Composites runs no tests of its own. Each measured value comes from a published test program.
Sources
Each row is one source the results are checked against. Error is the difference between the program's value and the source's value, as a percentage of the source's value. A reference case passes at 1 % or less, a lab case at 10 % or less. Open a row to see every case, its chart and how to reproduce each number.
Card, M. F., Experiments to Determine the Strength of Filament-Wound Cylinders Loaded in Axial Compression, NASA TN D-3522 (1966).
Measured [kN]
A lab case passes at ±10 % or less. Points outside this band are known gaps, listed below with the reason.
Cases, largest error first
| Case | Reference | Ours | Error | Status |
|---|---|---|---|---|
| Axial buckling load, cylinder 22 (±67.5/90, material 1, buckling and material failure) axial buckling load P [kN], classical buckling loadWhy: The tube page multiplies the classical buckling load by a knock-down factor for imperfect shells. That factor is a lower bound. These cylinders reached 65 to 80 % of the classical load, so the knocked-down load falls more than 15 % below the test, on the safe side. Where the classical load also misses by more than 15 %, the paper attributes part of the gap to the nonlinear stress-strain curve of the resin. | 98.3 | 150.62 | +53.2 % | Known gap |
| Axial buckling load, cylinder 23 (±67.5/90, material 1, buckling and material failure) axial buckling load P [kN], classical buckling loadWhy: The tube page multiplies the classical buckling load by a knock-down factor for imperfect shells. That factor is a lower bound. These cylinders reached 65 to 80 % of the classical load, so the knocked-down load falls more than 15 % below the test, on the safe side. Where the classical load also misses by more than 15 %, the paper attributes part of the gap to the nonlinear stress-strain curve of the resin. | 94.7 | 141.26 | +49.2 % | Known gap |
| Axial buckling load, cylinder 9 (±67.5/90, material 1, buckling and material failure) axial buckling load P [kN], classical buckling loadWhy: The tube page multiplies the classical buckling load by a knock-down factor for imperfect shells. That factor is a lower bound. These cylinders reached 65 to 80 % of the classical load, so the knocked-down load falls more than 15 % below the test, on the safe side. Where the classical load also misses by more than 15 %, the paper attributes part of the gap to the nonlinear stress-strain curve of the resin. | 117 | 173.33 | +48.1 % | Known gap |
| Axial buckling load, cylinder 8 (±67.5/90, material 1, buckling and material failure) axial buckling load P [kN], classical buckling loadWhy: The tube page multiplies the classical buckling load by a knock-down factor for imperfect shells. That factor is a lower bound. These cylinders reached 65 to 80 % of the classical load, so the knocked-down load falls more than 15 % below the test, on the safe side. Where the classical load also misses by more than 15 %, the paper attributes part of the gap to the nonlinear stress-strain curve of the resin. | 104 | 153.88 | +48.0 % | Known gap |
| Axial buckling load, cylinder 7 (±67.5/90, material 1, buckling and material failure) axial buckling load P [kN], classical buckling loadWhy: The tube page multiplies the classical buckling load by a knock-down factor for imperfect shells. That factor is a lower bound. These cylinders reached 65 to 80 % of the classical load, so the knocked-down load falls more than 15 % below the test, on the safe side. Where the classical load also misses by more than 15 %, the paper attributes part of the gap to the nonlinear stress-strain curve of the resin. | 114 | 166.21 | +45.8 % | Known gap |
| Axial buckling load, cylinder 10 (±25/90, material 2) axial buckling load P [kN], knocked-down buckling loadWhy: The tube page multiplies the classical buckling load by a knock-down factor for imperfect shells. That factor is a lower bound. These cylinders reached 65 to 80 % of the classical load, so the knocked-down load falls more than 15 % below the test, on the safe side. Where the classical load also misses by more than 15 %, the paper attributes part of the gap to the nonlinear stress-strain curve of the resin. | 140 | 77.874 | −44.4 % | Known gap |
| Axial buckling load, cylinder 24 (±25/90, material 2) axial buckling load P [kN], knocked-down buckling loadWhy: The tube page multiplies the classical buckling load by a knock-down factor for imperfect shells. That factor is a lower bound. These cylinders reached 65 to 80 % of the classical load, so the knocked-down load falls more than 15 % below the test, on the safe side. Where the classical load also misses by more than 15 %, the paper attributes part of the gap to the nonlinear stress-strain curve of the resin. | 127 | 72.35 | −43.0 % | Known gap |
| Axial buckling load, cylinder 21 (±45/90, material 1) axial buckling load P [kN], classical buckling loadWhy: The tube page multiplies the classical buckling load by a knock-down factor for imperfect shells. That factor is a lower bound. These cylinders reached 65 to 80 % of the classical load, so the knocked-down load falls more than 15 % below the test, on the safe side. Where the classical load also misses by more than 15 %, the paper attributes part of the gap to the nonlinear stress-strain curve of the resin. | 100 | 141.05 | +41.0 % | Known gap |
| Axial buckling load, cylinder 35 (±25/90, material 3) axial buckling load P [kN], knocked-down buckling loadWhy: The tube page multiplies the classical buckling load by a knock-down factor for imperfect shells. That factor is a lower bound. These cylinders reached 65 to 80 % of the classical load, so the knocked-down load falls more than 15 % below the test, on the safe side. Where the classical load also misses by more than 15 %, the paper attributes part of the gap to the nonlinear stress-strain curve of the resin. | 154 | 90.91 | −41.0 % | Known gap |
| Axial buckling load, cylinder 3 (±25/90, material 1) axial buckling load P [kN], knocked-down buckling loadWhy: The tube page multiplies the classical buckling load by a knock-down factor for imperfect shells. That factor is a lower bound. These cylinders reached 65 to 80 % of the classical load, so the knocked-down load falls more than 15 % below the test, on the safe side. Where the classical load also misses by more than 15 %, the paper attributes part of the gap to the nonlinear stress-strain curve of the resin. | 148 | 87.627 | −40.8 % | Known gap |
| Axial buckling load, cylinder 34 (±25/90, material 3) axial buckling load P [kN], knocked-down buckling loadWhy: The tube page multiplies the classical buckling load by a knock-down factor for imperfect shells. That factor is a lower bound. These cylinders reached 65 to 80 % of the classical load, so the knocked-down load falls more than 15 % below the test, on the safe side. Where the classical load also misses by more than 15 %, the paper attributes part of the gap to the nonlinear stress-strain curve of the resin. | 155 | 92.125 | −40.6 % | Known gap |
| Axial buckling load, cylinder 1 (±25/90, material 1) axial buckling load P [kN], knocked-down buckling loadWhy: The tube page multiplies the classical buckling load by a knock-down factor for imperfect shells. That factor is a lower bound. These cylinders reached 65 to 80 % of the classical load, so the knocked-down load falls more than 15 % below the test, on the safe side. Where the classical load also misses by more than 15 %, the paper attributes part of the gap to the nonlinear stress-strain curve of the resin. | 148 | 88.514 | −40.2 % | Known gap |
| Axial buckling load, cylinder 13 (±25/90, material 1) axial buckling load P [kN], knocked-down buckling loadWhy: The tube page multiplies the classical buckling load by a knock-down factor for imperfect shells. That factor is a lower bound. These cylinders reached 65 to 80 % of the classical load, so the knocked-down load falls more than 15 % below the test, on the safe side. Where the classical load also misses by more than 15 %, the paper attributes part of the gap to the nonlinear stress-strain curve of the resin. | 135 | 82.508 | −38.9 % | Known gap |
| Axial buckling load, cylinder 20 (±45/90, material 1) axial buckling load P [kN], classical buckling loadWhy: The tube page multiplies the classical buckling load by a knock-down factor for imperfect shells. That factor is a lower bound. These cylinders reached 65 to 80 % of the classical load, so the knocked-down load falls more than 15 % below the test, on the safe side. Where the classical load also misses by more than 15 %, the paper attributes part of the gap to the nonlinear stress-strain curve of the resin. | 100 | 138.78 | +38.8 % | Known gap |
| Axial buckling load, cylinder 11 (±25/90, material 3) axial buckling load P [kN], knocked-down buckling loadWhy: The tube page multiplies the classical buckling load by a knock-down factor for imperfect shells. That factor is a lower bound. These cylinders reached 65 to 80 % of the classical load, so the knocked-down load falls more than 15 % below the test, on the safe side. Where the classical load also misses by more than 15 %, the paper attributes part of the gap to the nonlinear stress-strain curve of the resin. | 149 | 91.62 | −38.5 % | Known gap |
| Axial buckling load, cylinder 12 (±25/90, material 1) axial buckling load P [kN], knocked-down buckling loadWhy: The tube page multiplies the classical buckling load by a knock-down factor for imperfect shells. That factor is a lower bound. These cylinders reached 65 to 80 % of the classical load, so the knocked-down load falls more than 15 % below the test, on the safe side. Where the classical load also misses by more than 15 %, the paper attributes part of the gap to the nonlinear stress-strain curve of the resin. | 126 | 77.683 | −38.3 % | Known gap |
| Axial buckling load, cylinder 6 (±45/90, material 1) axial buckling load P [kN], knocked-down buckling loadWhy: The tube page multiplies the classical buckling load by a knock-down factor for imperfect shells. That factor is a lower bound. These cylinders reached 65 to 80 % of the classical load, so the knocked-down load falls more than 15 % below the test, on the safe side. Where the classical load also misses by more than 15 %, the paper attributes part of the gap to the nonlinear stress-strain curve of the resin. | 104 | 65.584 | −36.9 % | Known gap |
| Axial buckling load, cylinder 5 (±45/90, material 1) axial buckling load P [kN], classical buckling loadWhy: The tube page multiplies the classical buckling load by a knock-down factor for imperfect shells. That factor is a lower bound. These cylinders reached 65 to 80 % of the classical load, so the knocked-down load falls more than 15 % below the test, on the safe side. Where the classical load also misses by more than 15 %, the paper attributes part of the gap to the nonlinear stress-strain curve of the resin. | 121 | 164.08 | +35.6 % | Known gap |
| Axial buckling load, cylinder 25 (±25/90, material 2) axial buckling load P [kN], knocked-down buckling loadWhy: The tube page multiplies the classical buckling load by a knock-down factor for imperfect shells. That factor is a lower bound. These cylinders reached 65 to 80 % of the classical load, so the knocked-down load falls more than 15 % below the test, on the safe side. Where the classical load also misses by more than 15 %, the paper attributes part of the gap to the nonlinear stress-strain curve of the resin. | 125 | 80.513 | −35.6 % | Known gap |
| Axial buckling load, cylinder 2 (±25/90, material 1) axial buckling load P [kN], knocked-down buckling loadWhy: The tube page multiplies the classical buckling load by a knock-down factor for imperfect shells. That factor is a lower bound. These cylinders reached 65 to 80 % of the classical load, so the knocked-down load falls more than 15 % below the test, on the safe side. Where the classical load also misses by more than 15 %, the paper attributes part of the gap to the nonlinear stress-strain curve of the resin. | 137 | 89.261 | −34.8 % | Known gap |
| Axial buckling load, cylinder 4 (±45/90, material 1) axial buckling load P [kN], classical buckling loadWhy: The tube page multiplies the classical buckling load by a knock-down factor for imperfect shells. That factor is a lower bound. These cylinders reached 65 to 80 % of the classical load, so the knocked-down load falls more than 15 % below the test, on the safe side. Where the classical load also misses by more than 15 %, the paper attributes part of the gap to the nonlinear stress-strain curve of the resin. | 120 | 161.79 | +34.8 % | Known gap |
| Axial buckling load, cylinder 14 (±25/90, material 1) axial buckling load P [kN], knocked-down buckling loadWhy: The tube page multiplies the classical buckling load by a knock-down factor for imperfect shells. That factor is a lower bound. These cylinders reached 65 to 80 % of the classical load, so the knocked-down load falls more than 15 % below the test, on the safe side. Where the classical load also misses by more than 15 %, the paper attributes part of the gap to the nonlinear stress-strain curve of the resin. | 125 | 85.15 | −31.9 % | Known gap |
| Axial buckling load, cylinder 15 (±25/90, material 1) axial buckling load P [kN], knocked-down buckling loadWhy: The tube page multiplies the classical buckling load by a knock-down factor for imperfect shells. That factor is a lower bound. These cylinders reached 65 to 80 % of the classical load, so the knocked-down load falls more than 15 % below the test, on the safe side. Where the classical load also misses by more than 15 %, the paper attributes part of the gap to the nonlinear stress-strain curve of the resin. | 127 | 86.887 | −31.6 % | Known gap |
How to reproduce it
Source
Card, M. F., Experiments to Determine the Strength of Filament-Wound Cylinders Loaded in Axial Compression, NASA TN D-3522 (1966).
Table III(b); constituents Table I(b)
What was taken from it
The maximum axial load of each of the 23 unheated cylinders that buckled, with the wall thickness and fiber volume fraction measured on that cylinder. Each case shows two values: the knocked-down load that the tube page reports, and the classical load before the knock-down.
Quantity compared: axial buckling load P [kN]
Inputs
- E-glass fiber: E = 72.40 GPa, ν = 0.23 (Table I(b))
- Three epoxy resins: E = 3.10, 3.33 and 3.52 GPa, ν = 0.40, 0.39 and 0.36 (Table I(b))
- Lamina from the app's Halpin-Tsai model at each cylinder's measured fiber volume fraction, with the app's own factors
- Inside diameter and length 381 mm; wall of three +α, -α, 90 groups, helical plies 60 % of the wall as in the paper
- Knock-down factor: the tube page's axial factor for imperfect shells, computed from the radius and the equivalent wall thickness
- Every knocked-down load falls 19.6 to 44.4 % below the test, on the safe side. The knock-down factor is a lower bound, and these cylinders reached 65 to 80 % of the classical load.
The inputs of each configuration are listed in the table below.
Allowed difference
±15 %
Compared values, largest error first
| Value | Layup | Reference | Ours | Error |
|---|---|---|---|---|
| Axial buckling load, cylinder 22 (±67.5/90, material 1, buckling and material failure), classical buckling load | none | 98.3 | 150.62 | +53.2 % |
| Axial buckling load, cylinder 23 (±67.5/90, material 1, buckling and material failure), classical buckling load | none | 94.7 | 141.26 | +49.2 % |
| Axial buckling load, cylinder 9 (±67.5/90, material 1, buckling and material failure), classical buckling load | none | 117 | 173.33 | +48.1 % |
| Axial buckling load, cylinder 8 (±67.5/90, material 1, buckling and material failure), classical buckling load | none | 104 | 153.88 | +48.0 % |
| Axial buckling load, cylinder 7 (±67.5/90, material 1, buckling and material failure), classical buckling load | none | 114 | 166.21 | +45.8 % |
| Axial buckling load, cylinder 10 (±25/90, material 2), knocked-down buckling load | none | 140 | 77.874 | −44.4 % |
| Axial buckling load, cylinder 24 (±25/90, material 2), knocked-down buckling load | none | 127 | 72.35 | −43.0 % |
| Axial buckling load, cylinder 21 (±45/90, material 1), classical buckling load | none | 100 | 141.05 | +41.0 % |
| Axial buckling load, cylinder 35 (±25/90, material 3), knocked-down buckling load | none | 154 | 90.91 | −41.0 % |
| Axial buckling load, cylinder 3 (±25/90, material 1), knocked-down buckling load | none | 148 | 87.627 | −40.8 % |
| Axial buckling load, cylinder 34 (±25/90, material 3), knocked-down buckling load | none | 155 | 92.125 | −40.6 % |
| Axial buckling load, cylinder 1 (±25/90, material 1), knocked-down buckling load | none | 148 | 88.514 | −40.2 % |
| Axial buckling load, cylinder 13 (±25/90, material 1), knocked-down buckling load | none | 135 | 82.508 | −38.9 % |
| Axial buckling load, cylinder 20 (±45/90, material 1), classical buckling load | none | 100 | 138.78 | +38.8 % |
| Axial buckling load, cylinder 11 (±25/90, material 3), knocked-down buckling load | none | 149 | 91.62 | −38.5 % |
| Axial buckling load, cylinder 12 (±25/90, material 1), knocked-down buckling load | none | 126 | 77.683 | −38.3 % |
| Axial buckling load, cylinder 6 (±45/90, material 1), knocked-down buckling load | none | 104 | 65.584 | −36.9 % |
| Axial buckling load, cylinder 5 (±45/90, material 1), classical buckling load | none | 121 | 164.08 | +35.6 % |
| Axial buckling load, cylinder 25 (±25/90, material 2), knocked-down buckling load | none | 125 | 80.513 | −35.6 % |
| Axial buckling load, cylinder 2 (±25/90, material 1), knocked-down buckling load | none | 137 | 89.261 | −34.8 % |
| Axial buckling load, cylinder 4 (±45/90, material 1), classical buckling load | none | 120 | 161.79 | +34.8 % |
| Axial buckling load, cylinder 14 (±25/90, material 1), knocked-down buckling load | none | 125 | 85.15 | −31.9 % |
| Axial buckling load, cylinder 15 (±25/90, material 1), knocked-down buckling load | none | 127 | 86.887 | −31.6 % |
| Axial buckling load, cylinder 15 (±25/90, material 1), classical buckling load | none | 127 | 164.01 | +29.1 % |
| Axial buckling load, cylinder 20 (±45/90, material 1), knocked-down buckling load | none | 100 | 71.319 | −28.7 % |
| Axial buckling load, cylinder 14 (±25/90, material 1), classical buckling load | none | 125 | 160.74 | +28.6 % |
| Axial buckling load, cylinder 4 (±45/90, material 1), knocked-down buckling load | none | 120 | 86.083 | −28.3 % |
| Axial buckling load, cylinder 5 (±45/90, material 1), knocked-down buckling load | none | 121 | 87.671 | −27.5 % |
| Axial buckling load, cylinder 21 (±45/90, material 1), knocked-down buckling load | none | 100 | 72.664 | −27.3 % |
| Axial buckling load, cylinder 25 (±25/90, material 2), classical buckling load | none | 125 | 155.53 | +24.4 % |
| Axial buckling load, cylinder 6 (±45/90, material 1), classical buckling load | none | 104 | 128.61 | +23.7 % |
| Axial buckling load, cylinder 2 (±25/90, material 1), classical buckling load | none | 137 | 167.77 | +22.5 % |
| Axial buckling load, cylinder 23 (±67.5/90, material 1, buckling and material failure), knocked-down buckling load | none | 94.7 | 73.822 | −22.0 % |
| Axial buckling load, cylinder 7 (±67.5/90, material 1, buckling and material failure), knocked-down buckling load | none | 114 | 88.982 | −21.9 % |
| Axial buckling load, cylinder 8 (±67.5/90, material 1, buckling and material failure), knocked-down buckling load | none | 104 | 81.506 | −21.6 % |
| Axial buckling load, cylinder 9 (±67.5/90, material 1, buckling and material failure), knocked-down buckling load | none | 117 | 92.405 | −21.0 % |
| Axial buckling load, cylinder 22 (±67.5/90, material 1, buckling and material failure), knocked-down buckling load | none | 98.3 | 79.075 | −19.6 % |
| Axial buckling load, cylinder 12 (±25/90, material 1), classical buckling load | none | 126 | 148.64 | +18.0 % |
| Axial buckling load, cylinder 13 (±25/90, material 1), classical buckling load | none | 135 | 156.09 | +15.6 % |
| Axial buckling load, cylinder 11 (±25/90, material 3), classical buckling load | none | 149 | 172.21 | +15.6 % |
| Axial buckling load, cylinder 1 (±25/90, material 1), classical buckling load | none | 148 | 166.01 | +12.2 % |
| Axial buckling load, cylinder 34 (±25/90, material 3), classical buckling load | none | 155 | 173.53 | +12.0 % |
| Axial buckling load, cylinder 24 (±25/90, material 2), classical buckling load | none | 127 | 141.89 | +11.7 % |
| Axial buckling load, cylinder 35 (±25/90, material 3), classical buckling load | none | 154 | 171.61 | +11.4 % |
| Axial buckling load, cylinder 3 (±25/90, material 1), classical buckling load | none | 148 | 164.35 | +11.0 % |
| Axial buckling load, cylinder 10 (±25/90, material 2), classical buckling load | none | 140 | 150.06 | +7.19 % |
Wall, L. D. Jr. & Card, M. F., Torsional Shear Strength of Filament-Wound Glass-Epoxy Tubes, NASA TN D-6140 (1971).
Measured [MPa]
A lab case passes at ±10 % or less. Points outside this band are known gaps, listed below with the reason.
Cases, largest error first
| Case | Reference | Ours | Error | Status |
|---|---|---|---|---|
| Wall shear modulus, specimen 24 (90, E-glass/epoxy) wall shear modulus G_xy [MPa], wall shear modulusWhy: The lamina comes from the fiber and resin moduli through the app’s Halpin-Tsai model, with no fitted factor. For this tube the prediction falls more than 15 % below the measured modulus. | 9300 | 6055 | −34.9 % | Known gap |
| Wall shear modulus, specimen 23 (90, E-glass/epoxy) wall shear modulus G_xy [MPa], wall shear modulusWhy: The lamina comes from the fiber and resin moduli through the app’s Halpin-Tsai model, with no fitted factor. For this tube the prediction falls more than 15 % below the measured modulus. | 8800 | 5731.4 | −34.9 % | Known gap |
| Wall shear modulus, specimen 19 (±75, E-glass/epoxy) wall shear modulus G_xy [MPa], wall shear modulusWhy: The lamina comes from the fiber and resin moduli through the app’s Halpin-Tsai model, with no fitted factor. For this tube the prediction falls more than 15 % below the measured modulus. | 9500 | 6595.5 | −30.6 % | Known gap |
| Wall shear modulus, specimen 21 (90, E-glass/epoxy) wall shear modulus G_xy [MPa], wall shear modulusWhy: The lamina comes from the fiber and resin moduli through the app’s Halpin-Tsai model, with no fitted factor. For this tube the prediction falls more than 15 % below the measured modulus. | 8100 | 5685.7 | −29.8 % | Known gap |
| Wall shear modulus, specimen 22 (90, E-glass/epoxy) wall shear modulus G_xy [MPa], wall shear modulusWhy: The lamina comes from the fiber and resin moduli through the app’s Halpin-Tsai model, with no fitted factor. For this tube the prediction falls more than 15 % below the measured modulus. | 7990 | 5644.1 | −29.4 % | Known gap |
| Wall shear modulus, specimen 20 (±75, E-glass/epoxy) wall shear modulus G_xy [MPa], wall shear modulusWhy: The lamina comes from the fiber and resin moduli through the app’s Halpin-Tsai model, with no fitted factor. For this tube the prediction falls more than 15 % below the measured modulus. | 9500 | 6931.2 | −27.0 % | Known gap |
| Wall shear modulus, specimen 25 (±15/90, E-glass/epoxy) wall shear modulus G_xy [MPa], wall shear modulusWhy: The lamina comes from the fiber and resin moduli through the app’s Halpin-Tsai model, with no fitted factor. For this tube the prediction falls more than 15 % below the measured modulus. | 9600 | 7020.7 | −26.9 % | Known gap |
| Wall shear modulus, specimen 17 (±75, E-glass/epoxy) wall shear modulus G_xy [MPa], wall shear modulusWhy: The lamina comes from the fiber and resin moduli through the app’s Halpin-Tsai model, with no fitted factor. For this tube the prediction falls more than 15 % below the measured modulus. | 10100 | 7500.8 | −25.7 % | Known gap |
| Wall shear modulus, specimen 18 (±75, E-glass/epoxy) wall shear modulus G_xy [MPa], wall shear modulusWhy: The lamina comes from the fiber and resin moduli through the app’s Halpin-Tsai model, with no fitted factor. For this tube the prediction falls more than 15 % below the measured modulus. | 9900 | 7418.5 | −25.1 % | Known gap |
| Wall shear modulus, specimen 2 (±15, E-glass/epoxy) wall shear modulus G_xy [MPa], wall shear modulusWhy: The lamina comes from the fiber and resin moduli through the app’s Halpin-Tsai model, with no fitted factor. For this tube the prediction falls more than 15 % below the measured modulus. | 7700 | 6015 | −21.9 % | Known gap |
| Wall shear modulus, specimen 3 (±15, E-glass/epoxy) wall shear modulus G_xy [MPa], wall shear modulusWhy: The lamina comes from the fiber and resin moduli through the app’s Halpin-Tsai model, with no fitted factor. For this tube the prediction falls more than 15 % below the measured modulus. | 8100 | 6387.9 | −21.1 % | Known gap |
| Wall shear modulus, specimen 28 (±15/90, E-glass/epoxy) wall shear modulus G_xy [MPa], wall shear modulusWhy: The lamina comes from the fiber and resin moduli through the app’s Halpin-Tsai model, with no fitted factor. For this tube the prediction falls more than 15 % below the measured modulus. | 9000 | 7281.9 | −19.1 % | Known gap |
| Wall shear modulus, specimen 15 (±60, E-glass/epoxy) wall shear modulus G_xy [MPa], wall shear modulusWhy: The lamina comes from the fiber and resin moduli through the app’s Halpin-Tsai model, with no fitted factor. For this tube the prediction falls more than 15 % below the measured modulus. | 14800 | 12028 | −18.7 % | Known gap |
| Wall shear modulus, specimen 26 (±15/90, E-glass/epoxy) wall shear modulus G_xy [MPa], wall shear modulusWhy: The lamina comes from the fiber and resin moduli through the app’s Halpin-Tsai model, with no fitted factor. For this tube the prediction falls more than 15 % below the measured modulus. | 9100 | 7407.8 | −18.6 % | Known gap |
| Wall shear modulus, specimen 27 (±15/90, E-glass/epoxy) wall shear modulus G_xy [MPa], wall shear modulusWhy: The lamina comes from the fiber and resin moduli through the app’s Halpin-Tsai model, with no fitted factor. For this tube the prediction falls more than 15 % below the measured modulus. | 9000 | 7374.6 | −18.1 % | Known gap |
| Wall shear modulus, specimen 29 (±30/90, E-glass/epoxy) wall shear modulus G_xy [MPa], wall shear modulusWhy: The lamina comes from the fiber and resin moduli through the app’s Halpin-Tsai model, with no fitted factor. For this tube the prediction falls more than 15 % below the measured modulus. | 11900 | 9752.4 | −18.0 % | Known gap |
| Wall shear modulus, specimen 8 (±30, E-glass/epoxy) wall shear modulus G_xy [MPa], wall shear modulusWhy: The lamina comes from the fiber and resin moduli through the app’s Halpin-Tsai model, with no fitted factor. For this tube the prediction falls more than 15 % below the measured modulus. | 13200 | 10826 | −18.0 % | Known gap |
| Wall shear modulus, specimen 13 (±60, E-glass/epoxy) wall shear modulus G_xy [MPa], wall shear modulusWhy: The lamina comes from the fiber and resin moduli through the app’s Halpin-Tsai model, with no fitted factor. For this tube the prediction falls more than 15 % below the measured modulus. | 14800 | 12176 | −17.7 % | Known gap |
| Wall shear modulus, specimen 16 (±60, E-glass/epoxy) wall shear modulus G_xy [MPa], wall shear modulusWhy: The lamina comes from the fiber and resin moduli through the app’s Halpin-Tsai model, with no fitted factor. For this tube the prediction falls more than 15 % below the measured modulus. | 14800 | 12318 | −16.8 % | Known gap |
| Wall shear modulus, specimen 14 (±60, E-glass/epoxy) wall shear modulus G_xy [MPa], wall shear modulusWhy: The lamina comes from the fiber and resin moduli through the app’s Halpin-Tsai model, with no fitted factor. For this tube the prediction falls more than 15 % below the measured modulus. | 15200 | 12687 | −16.5 % | Known gap |
| Wall shear modulus, specimen 1 (±15, E-glass/epoxy) wall shear modulus G_xy [MPa], wall shear modulusWhy: The lamina comes from the fiber and resin moduli through the app’s Halpin-Tsai model, with no fitted factor. For this tube the prediction falls more than 15 % below the measured modulus. | 7300 | 6110.2 | −16.3 % | Known gap |
| Wall shear modulus, specimen 36 (±45/90, E-glass/epoxy) wall shear modulus G_xy [MPa], wall shear modulusWhy: The lamina comes from the fiber and resin moduli through the app’s Halpin-Tsai model, with no fitted factor. For this tube the prediction falls more than 15 % below the measured modulus. | 14200 | 11929 | −16.0 % | Known gap |
| Wall shear modulus, specimen 5 (±30, E-glass/epoxy) wall shear modulus G_xy [MPa], wall shear modulusWhy: The lamina comes from the fiber and resin moduli through the app’s Halpin-Tsai model, with no fitted factor. For this tube the prediction falls more than 15 % below the measured modulus. | 13400 | 11278 | −15.8 % | Known gap |
| Wall shear modulus, specimen 11 (±45, E-glass/epoxy) wall shear modulus G_xy [MPa], wall shear modulus | 16300 | 13971 | −14.3 % | Over 10 % |
| Wall shear modulus, specimen 32 (±30/90, E-glass/epoxy) wall shear modulus G_xy [MPa], wall shear modulus | 11300 | 9687.5 | −14.3 % | Over 10 % |
| Wall shear modulus, specimen 4 (±15, E-glass/epoxy) wall shear modulus G_xy [MPa], wall shear modulus | 8200 | 7046.7 | −14.1 % | Over 10 % |
| Wall shear modulus, specimen 33 (±45/90, E-glass/epoxy) wall shear modulus G_xy [MPa], wall shear modulus | 13400 | 11550 | −13.8 % | Over 10 % |
| Wall shear modulus, specimen 34 (±45/90, E-glass/epoxy) wall shear modulus G_xy [MPa], wall shear modulus | 13200 | 11434 | −13.4 % | Over 10 % |
| Wall shear modulus, specimen 6 (±30, E-glass/epoxy) wall shear modulus G_xy [MPa], wall shear modulus | 12800 | 11106 | −13.2 % | Over 10 % |
| Wall shear modulus, specimen 35 (±45/90, E-glass/epoxy) wall shear modulus G_xy [MPa], wall shear modulus | 13800 | 12036 | −12.8 % | Over 10 % |
| Wall shear modulus, specimen 10 (±45, E-glass/epoxy) wall shear modulus G_xy [MPa], wall shear modulus | 15700 | 13696 | −12.8 % | Over 10 % |
| Wall shear modulus, specimen 31 (±30/90, E-glass/epoxy) wall shear modulus G_xy [MPa], wall shear modulus | 11200 | 9835.1 | −12.2 % | Over 10 % |
| Wall shear modulus, specimen 30 (±30/90, E-glass/epoxy) wall shear modulus G_xy [MPa], wall shear modulus | 11300 | 9935.4 | −12.1 % | Over 10 % |
| Wall shear modulus, specimen 7 (±30, E-glass/epoxy) wall shear modulus G_xy [MPa], wall shear modulus | 12500 | 11090 | −11.3 % | Over 10 % |
| Wall shear modulus, specimen 12 (±45, E-glass/epoxy) wall shear modulus G_xy [MPa], wall shear modulus | 15400 | 14015 | −8.99 % | Within 10 % |
| Wall shear modulus, specimen 9 (±45, E-glass/epoxy) wall shear modulus G_xy [MPa], wall shear modulus | 14400 | 13649 | −5.22 % | Within 10 % |
How to reproduce it
Source
Wall, L. D. Jr. & Card, M. F., Torsional Shear Strength of Filament-Wound Glass-Epoxy Tubes, NASA TN D-6140 (1971).
Tables IV(a) and V(a); specimen geometry Tables II and III; constituents Table I(a)
What was taken from it
The measured wall shear modulus of each of the 36 tubes, with the winding angles, wall thickness and fiber volume fraction measured on that tube.
Quantity compared: wall shear modulus G_xy [MPa]
Inputs
- E-glass fiber: E = 72.40 GPa, ν = 0.23 (Table I(a))
- ERL 2256 epoxy: E = 4.37 GPa, ν = 0.40 (Table I(a))
- Lamina from the app's Halpin-Tsai model at each tube's measured fiber volume fraction, with the app's own factors (no factor fitted to these tubes)
- Inside diameter 76.2 mm; helical tubes wound as 10 equal layers +α, -α; hoop tubes as 12 equal layers +α, -α, 90
- Wall shear modulus taken from the tube's torsional stiffness at the mean wall radius
The inputs of each configuration are listed in the table below.
Allowed difference
±15 %
Compared values, largest error first
| Value | Layup | Reference | Ours | Error |
|---|---|---|---|---|
| Wall shear modulus, specimen 24 (90, E-glass/epoxy) | unidirectional | 9300 | 6055 | −34.9 % |
| Wall shear modulus, specimen 23 (90, E-glass/epoxy) | unidirectional | 8800 | 5731.4 | −34.9 % |
| Wall shear modulus, specimen 19 (±75, E-glass/epoxy) | angle-ply | 9500 | 6595.5 | −30.6 % |
| Wall shear modulus, specimen 21 (90, E-glass/epoxy) | unidirectional | 8100 | 5685.7 | −29.8 % |
| Wall shear modulus, specimen 22 (90, E-glass/epoxy) | unidirectional | 7990 | 5644.1 | −29.4 % |
| Wall shear modulus, specimen 20 (±75, E-glass/epoxy) | angle-ply | 9500 | 6931.2 | −27.0 % |
| Wall shear modulus, specimen 25 (±15/90, E-glass/epoxy) | none | 9600 | 7020.7 | −26.9 % |
| Wall shear modulus, specimen 17 (±75, E-glass/epoxy) | angle-ply | 10100 | 7500.8 | −25.7 % |
| Wall shear modulus, specimen 18 (±75, E-glass/epoxy) | angle-ply | 9900 | 7418.5 | −25.1 % |
| Wall shear modulus, specimen 2 (±15, E-glass/epoxy) | angle-ply | 7700 | 6015 | −21.9 % |
| Wall shear modulus, specimen 3 (±15, E-glass/epoxy) | angle-ply | 8100 | 6387.9 | −21.1 % |
| Wall shear modulus, specimen 28 (±15/90, E-glass/epoxy) | none | 9000 | 7281.9 | −19.1 % |
| Wall shear modulus, specimen 15 (±60, E-glass/epoxy) | angle-ply | 14800 | 12028 | −18.7 % |
| Wall shear modulus, specimen 26 (±15/90, E-glass/epoxy) | none | 9100 | 7407.8 | −18.6 % |
| Wall shear modulus, specimen 27 (±15/90, E-glass/epoxy) | none | 9000 | 7374.6 | −18.1 % |
| Wall shear modulus, specimen 29 (±30/90, E-glass/epoxy) | none | 11900 | 9752.4 | −18.0 % |
| Wall shear modulus, specimen 8 (±30, E-glass/epoxy) | angle-ply | 13200 | 10826 | −18.0 % |
| Wall shear modulus, specimen 13 (±60, E-glass/epoxy) | angle-ply | 14800 | 12176 | −17.7 % |
| Wall shear modulus, specimen 16 (±60, E-glass/epoxy) | angle-ply | 14800 | 12318 | −16.8 % |
| Wall shear modulus, specimen 14 (±60, E-glass/epoxy) | angle-ply | 15200 | 12687 | −16.5 % |
| Wall shear modulus, specimen 1 (±15, E-glass/epoxy) | angle-ply | 7300 | 6110.2 | −16.3 % |
| Wall shear modulus, specimen 36 (±45/90, E-glass/epoxy) | none | 14200 | 11929 | −16.0 % |
| Wall shear modulus, specimen 5 (±30, E-glass/epoxy) | angle-ply | 13400 | 11278 | −15.8 % |
| Wall shear modulus, specimen 11 (±45, E-glass/epoxy) | angle-ply | 16300 | 13971 | −14.3 % |
| Wall shear modulus, specimen 32 (±30/90, E-glass/epoxy) | none | 11300 | 9687.5 | −14.3 % |
| Wall shear modulus, specimen 4 (±15, E-glass/epoxy) | angle-ply | 8200 | 7046.7 | −14.1 % |
| Wall shear modulus, specimen 33 (±45/90, E-glass/epoxy) | none | 13400 | 11550 | −13.8 % |
| Wall shear modulus, specimen 34 (±45/90, E-glass/epoxy) | none | 13200 | 11434 | −13.4 % |
| Wall shear modulus, specimen 6 (±30, E-glass/epoxy) | angle-ply | 12800 | 11106 | −13.2 % |
| Wall shear modulus, specimen 35 (±45/90, E-glass/epoxy) | none | 13800 | 12036 | −12.8 % |
| Wall shear modulus, specimen 10 (±45, E-glass/epoxy) | angle-ply | 15700 | 13696 | −12.8 % |
| Wall shear modulus, specimen 31 (±30/90, E-glass/epoxy) | none | 11200 | 9835.1 | −12.2 % |
| Wall shear modulus, specimen 30 (±30/90, E-glass/epoxy) | none | 11300 | 9935.4 | −12.1 % |
| Wall shear modulus, specimen 7 (±30, E-glass/epoxy) | angle-ply | 12500 | 11090 | −11.3 % |
| Wall shear modulus, specimen 12 (±45, E-glass/epoxy) | angle-ply | 15400 | 14015 | −8.99 % |
| Wall shear modulus, specimen 9 (±45, E-glass/epoxy) | angle-ply | 14400 | 13649 | −5.22 % |
Card, M. F., Experiments to Determine Elastic Moduli for Filament-Wound Cylinders, NASA TN D-3111 (1965).
Measured [GPa]
A lab case passes at ±10 % or less. Points outside this band are known gaps, listed below with the reason.
Cases, largest error first
| Case | Reference | Ours | Error | Status |
|---|---|---|---|---|
| in-plane shear modulus, tube 7 (±90/90, 6.604 cm bore) in-plane shear modulus [GPa], in-plane shear modulusWhy: The lamina comes from the fiber and resin moduli through the app’s Halpin-Tsai model, with no fitted factor. For this specimen the predicted modulus is outside ±15 % of the measured modulus. | 7.52 | 5.5769 | −25.8 % | Known gap |
| in-plane shear modulus, tube 6 (±67.5/90, 6.604 cm bore) in-plane shear modulus [GPa], in-plane shear modulusWhy: The lamina comes from the fiber and resin moduli through the app’s Halpin-Tsai model, with no fitted factor. For this specimen the predicted modulus is outside ±15 % of the measured modulus. | 10.76 | 8.6624 | −19.5 % | Known gap |
| axial modulus, tube 8 (±90/90, 6.604 cm bore) axial modulus [GPa], axial modulusWhy: The lamina comes from the fiber and resin moduli through the app’s Halpin-Tsai model, with no fitted factor. For this specimen the predicted modulus is outside ±15 % of the measured modulus. | 14.34 | 16.523 | +15.2 % | Known gap |
| in-plane shear modulus, tube 3 (±67.5/90, 6.604 cm bore) in-plane shear modulus [GPa], in-plane shear modulus | 9.58 | 8.4145 | −12.2 % | Over 10 % |
| axial modulus, tube 5 (±67.5/90, 6.604 cm bore) axial modulus [GPa], axial modulus | 20.82 | 18.739 | −10.00 % | Within 10 % |
| in-plane shear modulus, tube 5 (±67.5/90, 6.604 cm bore) in-plane shear modulus [GPa], in-plane shear modulus | 9.79 | 8.8128 | −9.98 % | Within 10 % |
| hoop modulus, cylinder 4 (±45/90, 38.1 cm bore) hoop modulus [GPa], hoop modulus | 30.34 | 27.456 | −9.51 % | Within 10 % |
| in-plane shear modulus, tube 4 (±67.5/90, 6.604 cm bore) in-plane shear modulus [GPa], in-plane shear modulus | 9.72 | 8.8128 | −9.33 % | Within 10 % |
| hoop modulus, cylinder 5 (±45/90, 38.1 cm bore) hoop modulus [GPa], hoop modulus | 29.86 | 27.105 | −9.22 % | Within 10 % |
| axial modulus, cylinder 8 (±67.5/90, 38.1 cm bore) axial modulus [GPa], axial modulus | 16.69 | 15.223 | −8.79 % | Within 10 % |
| axial modulus, cylinder 7 (±67.5/90, 38.1 cm bore) axial modulus [GPa], axial modulus | 16.82 | 15.356 | −8.70 % | Within 10 % |
| axial modulus, cylinder 4 (±45/90, 38.1 cm bore) axial modulus [GPa], axial modulus | 17.86 | 16.369 | −8.35 % | Within 10 % |
| hoop modulus, cylinder 1 (±25/90, 38.1 cm bore) hoop modulus [GPa], hoop modulus | 29.03 | 26.803 | −7.67 % | Within 10 % |
| axial modulus, cylinder 5 (±45/90, 38.1 cm bore) axial modulus [GPa], axial modulus | 17.38 | 16.096 | −7.39 % | Within 10 % |
| axial modulus, tube 1 (±45/90, 6.604 cm bore) axial modulus [GPa], axial modulus | 21.17 | 19.619 | −7.33 % | Within 10 % |
| in-plane shear modulus, tube 8 (±90/90, 6.604 cm bore) in-plane shear modulus [GPa], in-plane shear modulus | 5.1 | 4.7418 | −7.02 % | Within 10 % |
| axial modulus, tube 2 (±45/90, 6.604 cm bore) axial modulus [GPa], axial modulus | 20.82 | 19.464 | −6.51 % | Within 10 % |
| axial modulus, cylinder 9 (±67.5/90, 38.1 cm bore) axial modulus [GPa], axial modulus | 18 | 16.843 | −6.43 % | Within 10 % |
| axial modulus, cylinder 6 (±45/90, 38.1 cm bore) axial modulus [GPa], axial modulus | 18.41 | 17.313 | −5.96 % | Within 10 % |
| axial modulus, tube 7 (±90/90, 6.604 cm bore) axial modulus [GPa], axial modulus | 18.34 | 19.328 | +5.39 % | Within 10 % |
| hoop modulus, cylinder 2 (±25/90, 38.1 cm bore) hoop modulus [GPa], hoop modulus | 28.96 | 27.413 | −5.34 % | Within 10 % |
| axial modulus, cylinder 10 (±25/90, 38.1 cm bore) axial modulus [GPa], axial modulus | 26.89 | 28.299 | +5.24 % | Within 10 % |
| hoop modulus, cylinder 10 (±25/90, 38.1 cm bore) hoop modulus [GPa], hoop modulus | 30.27 | 28.736 | −5.07 % | Within 10 % |
| hoop modulus, cylinder 11 (±25/90, 38.1 cm bore) hoop modulus [GPa], hoop modulus | 29.17 | 27.82 | −4.63 % | Within 10 % |
| hoop modulus, cylinder 8 (±67.5/90, 38.1 cm bore) hoop modulus [GPa], hoop modulus | 42.68 | 40.789 | −4.43 % | Within 10 % |
| axial modulus, cylinder 2 (±25/90, 38.1 cm bore) axial modulus [GPa], axial modulus | 25.86 | 26.969 | +4.29 % | Within 10 % |
| hoop modulus, cylinder 7 (±67.5/90, 38.1 cm bore) hoop modulus [GPa], hoop modulus | 42.75 | 40.979 | −4.14 % | Within 10 % |
| axial modulus, cylinder 1 (±25/90, 38.1 cm bore) axial modulus [GPa], axial modulus | 25.44 | 26.364 | +3.63 % | Within 10 % |
| axial modulus, cylinder 3 (±25/90, 38.1 cm bore) axial modulus [GPa], axial modulus | 25.3 | 26.116 | +3.23 % | Within 10 % |
| axial modulus, cylinder 11 (±25/90, 38.1 cm bore) axial modulus [GPa], axial modulus | 26.68 | 27.398 | +2.69 % | Within 10 % |
| in-plane shear modulus, tube 1 (±45/90, 6.604 cm bore) in-plane shear modulus [GPa], in-plane shear modulus | 11.1 | 11.356 | +2.31 % | Within 10 % |
| axial modulus, tube 4 (±67.5/90, 6.604 cm bore) axial modulus [GPa], axial modulus | 18.41 | 18.739 | +1.79 % | Within 10 % |
| axial modulus, tube 6 (±67.5/90, 6.604 cm bore) axial modulus [GPa], axial modulus | 18.06 | 18.323 | +1.45 % | Within 10 % |
| axial modulus, tube 3 (±67.5/90, 6.604 cm bore) axial modulus [GPa], axial modulus | 17.44 | 17.642 | +1.16 % | Within 10 % |
| in-plane shear modulus, tube 2 (±45/90, 6.604 cm bore) in-plane shear modulus [GPa], in-plane shear modulus | 11.38 | 11.289 | −0.80 % | Within 10 % |
| hoop modulus, cylinder 9 (±67.5/90, 38.1 cm bore) hoop modulus [GPa], hoop modulus | 42.75 | 42.964 | +0.50 % | Within 10 % |
| hoop modulus, cylinder 6 (±45/90, 38.1 cm bore) hoop modulus [GPa], hoop modulus | 28.75 | 28.637 | −0.39 % | Within 10 % |
How to reproduce it
Source
Card, M. F., Experiments to Determine Elastic Moduli for Filament-Wound Cylinders, NASA TN D-3111 (1965).
Tables II(b) and III(b); constituents Table I(b)
What was taken from it
The measured axial and hoop moduli of 11 cylinders with a 381 mm bore, and the axial and shear moduli of 8 tubes with a 66.04 mm bore, each with its own measured wall thickness and fiber volume fraction.
Quantity compared: axial modulus [GPa]; hoop modulus [GPa]; in-plane shear modulus [GPa]
Inputs
- E-glass fiber: E = 72.40 GPa, ν = 0.23 (Table I(b))
- Three epoxy resins: E = 3.10, 3.33 and 3.52 GPa, ν = 0.40, 0.39 and 0.36 (Table I(b)); the tubes use the first
- Lamina from the app's Halpin-Tsai model at each specimen's measured fiber volume fraction, with the app's own factors
- Wall of three +α, -α, 90 groups, helical plies 60 % of the wall as in the paper
- Moduli are the laminate's membrane engineering constants
The inputs of each configuration are listed in the table below.
Allowed difference
±15 %
Compared values, largest error first
| Value | Layup | Reference | Ours | Error |
|---|---|---|---|---|
| in-plane shear modulus, tube 7 (±90/90, 6.604 cm bore) | none | 7.52 | 5.5769 | −25.8 % |
| in-plane shear modulus, tube 6 (±67.5/90, 6.604 cm bore) | none | 10.76 | 8.6624 | −19.5 % |
| axial modulus, tube 8 (±90/90, 6.604 cm bore) | none | 14.34 | 16.523 | +15.2 % |
| in-plane shear modulus, tube 3 (±67.5/90, 6.604 cm bore) | none | 9.58 | 8.4145 | −12.2 % |
| axial modulus, tube 5 (±67.5/90, 6.604 cm bore) | none | 20.82 | 18.739 | −10.00 % |
| in-plane shear modulus, tube 5 (±67.5/90, 6.604 cm bore) | none | 9.79 | 8.8128 | −9.98 % |
| hoop modulus, cylinder 4 (±45/90, 38.1 cm bore) | none | 30.34 | 27.456 | −9.51 % |
| in-plane shear modulus, tube 4 (±67.5/90, 6.604 cm bore) | none | 9.72 | 8.8128 | −9.33 % |
| hoop modulus, cylinder 5 (±45/90, 38.1 cm bore) | none | 29.86 | 27.105 | −9.22 % |
| axial modulus, cylinder 8 (±67.5/90, 38.1 cm bore) | none | 16.69 | 15.223 | −8.79 % |
| axial modulus, cylinder 7 (±67.5/90, 38.1 cm bore) | none | 16.82 | 15.356 | −8.70 % |
| axial modulus, cylinder 4 (±45/90, 38.1 cm bore) | none | 17.86 | 16.369 | −8.35 % |
| hoop modulus, cylinder 1 (±25/90, 38.1 cm bore) | none | 29.03 | 26.803 | −7.67 % |
| axial modulus, cylinder 5 (±45/90, 38.1 cm bore) | none | 17.38 | 16.096 | −7.39 % |
| axial modulus, tube 1 (±45/90, 6.604 cm bore) | none | 21.17 | 19.619 | −7.33 % |
| in-plane shear modulus, tube 8 (±90/90, 6.604 cm bore) | none | 5.1 | 4.7418 | −7.02 % |
| axial modulus, tube 2 (±45/90, 6.604 cm bore) | none | 20.82 | 19.464 | −6.51 % |
| axial modulus, cylinder 9 (±67.5/90, 38.1 cm bore) | none | 18 | 16.843 | −6.43 % |
| axial modulus, cylinder 6 (±45/90, 38.1 cm bore) | none | 18.41 | 17.313 | −5.96 % |
| axial modulus, tube 7 (±90/90, 6.604 cm bore) | none | 18.34 | 19.328 | +5.39 % |
| hoop modulus, cylinder 2 (±25/90, 38.1 cm bore) | none | 28.96 | 27.413 | −5.34 % |
| axial modulus, cylinder 10 (±25/90, 38.1 cm bore) | none | 26.89 | 28.299 | +5.24 % |
| hoop modulus, cylinder 10 (±25/90, 38.1 cm bore) | none | 30.27 | 28.736 | −5.07 % |
| hoop modulus, cylinder 11 (±25/90, 38.1 cm bore) | none | 29.17 | 27.82 | −4.63 % |
| hoop modulus, cylinder 8 (±67.5/90, 38.1 cm bore) | none | 42.68 | 40.789 | −4.43 % |
| axial modulus, cylinder 2 (±25/90, 38.1 cm bore) | none | 25.86 | 26.969 | +4.29 % |
| hoop modulus, cylinder 7 (±67.5/90, 38.1 cm bore) | none | 42.75 | 40.979 | −4.14 % |
| axial modulus, cylinder 1 (±25/90, 38.1 cm bore) | none | 25.44 | 26.364 | +3.63 % |
| axial modulus, cylinder 3 (±25/90, 38.1 cm bore) | none | 25.3 | 26.116 | +3.23 % |
| axial modulus, cylinder 11 (±25/90, 38.1 cm bore) | none | 26.68 | 27.398 | +2.69 % |
| in-plane shear modulus, tube 1 (±45/90, 6.604 cm bore) | none | 11.1 | 11.356 | +2.31 % |
| axial modulus, tube 4 (±67.5/90, 6.604 cm bore) | none | 18.41 | 18.739 | +1.79 % |
| axial modulus, tube 6 (±67.5/90, 6.604 cm bore) | none | 18.06 | 18.323 | +1.45 % |
| axial modulus, tube 3 (±67.5/90, 6.604 cm bore) | none | 17.44 | 17.642 | +1.16 % |
| in-plane shear modulus, tube 2 (±45/90, 6.604 cm bore) | none | 11.38 | 11.289 | −0.80 % |
| hoop modulus, cylinder 9 (±67.5/90, 38.1 cm bore) | none | 42.75 | 42.964 | +0.50 % |
| hoop modulus, cylinder 6 (±45/90, 38.1 cm bore) | none | 28.75 | 28.637 | −0.39 % |
The tick on each bar marks the limit for that group. A bar past the tick is over the limit.
How the numbers are checked
The two groups answer two different questions. Reference solutions check that the program solves its equations correctly: the same model, solved by someone else in a published solution, an independent implementation or a finite element model, gives the same number. Engineers call this verification. Lab tests check that the equations describe a real part, which no amount of matching other programs can show. That is validation. A method can pass every verification case and still differ from a test, because the model leaves something out. The terms follow NAFEMS, What is Verification and Validation? (2014).
A reference case counts as within when its error is at most 1 %, a lab case when it is at most 10 %. A known gap is a case where the method and the reference disagree for a reason that is understood. It stays on this page with its reason until the method changes.