- Verification
- /
- Plates
Plate buckling and vibration verification
Plate bending, buckling and vibration results compared with lab tests, published tables and closed-form solutions.
How close the results are
Lab tests show how close a prediction comes to a measured part. Reference solutions show that the program solves its equations the way someone else solved the same problem. A case is one configuration checked against one source, and it scores by its value with the largest error. A lab case that runs every failure criterion or every micromechanics model scores by Puck (the Puck failure criterion or the Puck micromechanics model), the same choice for all of them. The other models show in its row. Fitted cases show in their source but stay out of every number.
Lab tests: strength
Validation: failure loads of coupons, tubes, beams and joints, compared with published test programs. Where the app has several failure criteria, a case scores by Puck. The other criteria show in its row.
No lab test of this kind is published for plates yet.
Published solutions
Verification: the same inputs run against worked examples, tables and closed-form answers printed in textbooks, NASA reports and journal papers.
- Cases
- 6 cases from 2 sources, 25 compared numbers
- Within 1 %
- 6 of 6
- Median error
- 0.0088 %
- Largest error
- 0.95 %
- Known gaps
- None
Finite element models
Verification: a plane-stress finite element model of the same problem, solved in an open-source code. Each model runs on two meshes.
No finite element model is listed for plates yet.
ABD Composites runs no tests of its own. Each measured value comes from a published test program.
Sources
Each row is one source the results are checked against. Error is the difference between the program's value and the source's value, as a percentage of the source's value. A reference case passes at 1 % or less, a lab case at 10 % or less. Open a row to see every case, its chart and how to reproduce each number.
Radloff, H. D., Buckling Response of Symmetrically Laminated Composite Plates Having a Trapezoidal Planform Area, MS thesis, Virginia Tech (1994).
Measured [-]
A lab case passes at ±10 % or less. Points outside this band are known gaps, listed below with the reason.
Cases, largest error first
| Case | Reference | Ours | Error | Status |
|---|---|---|---|---|
| Radloff compression buckling coefficient, [+30₆/-30₆]s square plate k_c = P·W/(π²√(D11·D22)) [-], k_cWhy: The thesis reports differences of up to 32 % between its own analysis and these ±30 tests. The prediction is above the test, on the unsafe side. | 7.6 | 10.174 | +33.9 % | Known gap |
| Radloff compression buckling coefficient, [+30/-30]6s square plate k_c = P·W/(π²√(D11·D22)) [-], k_cWhy: The thesis reports differences of up to 32 % between its own analysis and these ±30 tests. The prediction is above the test, on the unsafe side. | 9.1 | 11.839 | +30.1 % | Known gap |
| Radloff compression buckling coefficient, [0]24 square plate k_c = P·W/(π²√(D11·D22)) [-], k_cWhy: The thesis reports initial imperfections in the [0]24 specimens. The prediction is above the test, on the unsafe side. | 11 | 14.131 | +28.5 % | Known gap |
| Radloff compression buckling coefficient, [+60₆/-60₆]s square plate k_c = P·W/(π²√(D11·D22)) [-], k_c | 6.4 | 5.8052 | −9.29 % | Within 10 % |
| Radloff compression buckling coefficient, [+60/-60]6s square plate k_c = P·W/(π²√(D11·D22)) [-], k_c | 7.9 | 7.239 | −8.37 % | Within 10 % |
| Radloff compression buckling coefficient, [+45/-45]6s square plate k_c = P·W/(π²√(D11·D22)) [-], k_c | 8.7 | 9.134 | +4.99 % | Within 10 % |
| Radloff compression buckling coefficient, [+45/0/-45/90]3s square plate k_c = P·W/(π²√(D11·D22)) [-], k_c | 7.1 | 7.2629 | +2.29 % | Within 10 % |
| Radloff compression buckling coefficient, [90]24 square plate k_c = P·W/(π²√(D11·D22)) [-], k_c | 3.8 | 3.8417 | +1.10 % | Within 10 % |
| Radloff compression buckling coefficient, aluminum square plate k_c = P·W/(π²√(D11·D22)) [-], k_c | 6.6 | 6.6232 | +0.35 % | Within 10 % |
How to reproduce it
Source
Radloff, H. D., Buckling Response of Symmetrically Laminated Composite Plates Having a Trapezoidal Planform Area, MS thesis, Virginia Tech (1994).
Tables 6.2-6.5 (taper ratio 1.0, aspect ratio 1.0); ply properties Table 2.2; specimen size Table 5.1
What was taken from it
The measured buckling coefficient of each square plate. The trapezoidal plates are left out, because the solver handles rectangular plates only.
Quantity compared: k_c = P·W/(π²√(D11·D22)) [-]
Inputs
- AS4/3502 ply, Radloff Table 2.2: E1 127 GPa, E2 11.0 GPa, G12 5.73 GPa, ν12 0.35, nominal ply 0.127 mm, 24 plies
- Aluminum: E 72.0 GPa, ν 0.32
- Plates W 368 mm, L 375 mm, loaded ends clamped, sides simply supported (knife edges).
The inputs of each configuration are listed in the table below.
Allowed difference
15 %
Compared values, largest error first
| Value | Layup | Reference | Ours | Error |
|---|---|---|---|---|
| Radloff compression buckling coefficient, [+30₆/-30₆]s square plate | angle-ply | 7.6 | 10.174 | +33.9 % |
| Radloff compression buckling coefficient, [+30/-30]6s square plate | angle-ply | 9.1 | 11.839 | +30.1 % |
| Radloff compression buckling coefficient, [0]24 square plate | unidirectional | 11 | 14.131 | +28.5 % |
| Radloff compression buckling coefficient, [+60₆/-60₆]s square plate | angle-ply | 6.4 | 5.8052 | −9.29 % |
| Radloff compression buckling coefficient, [+60/-60]6s square plate | angle-ply | 7.9 | 7.239 | −8.37 % |
| Radloff compression buckling coefficient, [+45/-45]6s square plate | angle-ply | 8.7 | 9.134 | +4.99 % |
| Radloff compression buckling coefficient, [+45/0/-45/90]3s square plate | quasi-isotropic | 7.1 | 7.2629 | +2.29 % |
| Radloff compression buckling coefficient, [90]24 square plate | unidirectional | 3.8 | 3.8417 | +1.10 % |
| Radloff compression buckling coefficient, aluminum square plate | isotropic | 6.6 | 6.6232 | +0.35 % |
Bert, C. W. & Mayberry, B. L., "Free Vibrations of Unsymmetrically Laminated Anisotropic Plates with Clamped Edges", J Compos Mater 3 (1969) 282-293.
Measured [Hz]
A lab case passes at ±10 % or less. Points outside this band are known gaps, listed below with the reason.
Cases, largest error first
| Case | Reference | Ours | Error | Status |
|---|---|---|---|---|
| Bert & Mayberry clamped plate, two plies at 0°, fundamental mode f [Hz], fWhy: The paper's own analysis is below these tests too, and the paper attributes this to its estimated shear modulus. The plates also showed strong amplitude nonlinearity. | 112 | 82.848 | −26.0 % | Known gap |
| Bert & Mayberry clamped plate, two plies at 45°, fundamental mode f [Hz], fWhy: The paper's own analysis is below these tests too, and the paper attributes this to its estimated shear modulus. The plates also showed strong amplitude nonlinearity. | 104 | 81.168 | −22.0 % | Known gap |
| Bert & Mayberry clamped plate, four plies, top two at 0°, bottom two at 90°, fundamental mode f [Hz], f | 193 | 166.95 | −13.5 % | Over 10 % |
| Bert & Mayberry clamped plate, four plies, top two at 45°, bottom two at -45°, fundamental mode f [Hz], f | 167 | 162.34 | −2.79 % | Within 10 % |
How to reproduce it
Source
Bert, C. W. & Mayberry, B. L., "Free Vibrations of Unsymmetrically Laminated Anisotropic Plates with Clamped Edges", J Compos Mater 3 (1969) 282-293.
Table 2 (measured values in parentheses); ply properties Table 1
What was taken from it
The measured fundamental frequency of four plates, extrapolated to zero amplitude.
Quantity compared: f [Hz]
Inputs
- E-glass fabric/epoxy ply, Bert & Mayberry Table 1: E1 2.695e6 psi, E2 2.56e6 psi, G12 0.6e6 psi (an estimate in the paper), ν12 0.242, ply 0.0105 in
- Plates 9 x 6 in, all edges clamped.
The inputs of each configuration are listed in the table below.
Allowed difference
15 %
Compared values, largest error first
| Value | Layup | Reference | Ours | Error |
|---|---|---|---|---|
| Bert & Mayberry clamped plate, two plies at 0°, fundamental mode | woven fabric | 112 | 82.848 | −26.0 % |
| Bert & Mayberry clamped plate, two plies at 45°, fundamental mode | woven fabric | 104 | 81.168 | −22.0 % |
| Bert & Mayberry clamped plate, four plies, top two at 0°, bottom two at 90°, fundamental mode | unsymmetric | 193 | 166.95 | −13.5 % |
| Bert & Mayberry clamped plate, four plies, top two at 45°, bottom two at -45°, fundamental mode | unsymmetric | 167 | 162.34 | −2.79 % |
Kosteletos, S., Buckling and Postbuckling of Composite Plates under Shear Load, PhD thesis, University of Glasgow (1990).
Measured [N/mm]
A lab case passes at ±10 % or less. Points outside this band are known gaps, listed below with the reason.
Cases, largest error first
| Case | Reference | Ours | Error | Status |
|---|---|---|---|---|
| Ashton & Love shear buckling, (45,45,45,45)2s clamped plate (row 14) Nxy,cr [N/mm], Nxy,crWhy: The Ashton & Love analysis in the same table is 24 % and 27 % below these two tests as well. | 121.1 | 92.664 | −23.5 % | Known gap |
| Ashton & Love shear buckling, (45,45,45,45)2s clamped plate (row 13) Nxy,cr [N/mm], Nxy,crWhy: The Ashton & Love analysis in the same table is 24 % and 27 % below these two tests as well. | 138.6 | 110 | −20.6 % | Known gap |
| Ashton & Love shear buckling, (-45,45,-45,45)2s clamped plate (row 8) Nxy,cr [N/mm], Nxy,cr | 350.3 | 394.9 | +12.7 % | Over 10 % |
| Ashton & Love shear buckling, (0,90,0,90)2s clamped plate (row 4) Nxy,cr [N/mm], Nxy,cr | 241.4 | 265.9 | +10.2 % | Over 10 % |
| Ashton & Love shear buckling, (45,-45,45,-45)2s clamped plate (row 7) Nxy,cr [N/mm], Nxy,cr | 271.4 | 292.31 | +7.70 % | Within 10 % |
| Ashton & Love shear buckling, (0,-45,45,90)2s clamped plate (row 10) Nxy,cr [N/mm], Nxy,cr | 349.4 | 326 | −6.70 % | Within 10 % |
| Ashton & Love shear buckling, aluminum clamped plate (row AL02) Nxy,cr [N/mm], Nxy,cr | 288.1 | 306.32 | +6.32 % | Within 10 % |
| Ashton & Love shear buckling, (45,-45,45,-45)2s clamped plate (row 11) Nxy,cr [N/mm], Nxy,cr | 295.3 | 313.18 | +6.06 % | Within 10 % |
| Ashton & Love shear buckling, (45,-45,45,-45)2s clamped plate (row 12) Nxy,cr [N/mm], Nxy,cr | 333.3 | 313.18 | −6.04 % | Within 10 % |
| Ashton & Love shear buckling, (0,0,0,0)2s clamped plate (row 3) Nxy,cr [N/mm], Nxy,cr | 119 | 114.36 | −3.90 % | Within 10 % |
| Ashton & Love shear buckling, (90,45,-45,0)2s clamped plate (row 6) Nxy,cr [N/mm], Nxy,cr | 324 | 311.72 | −3.79 % | Within 10 % |
| Ashton & Love shear buckling, (0,-45,45,90)2s clamped plate (row 9) Nxy,cr [N/mm], Nxy,cr | 325.2 | 337.11 | +3.66 % | Within 10 % |
| Ashton & Love shear buckling, aluminum clamped plate (row AL01) Nxy,cr [N/mm], Nxy,cr | 770.9 | 796.3 | +3.30 % | Within 10 % |
| Ashton & Love shear buckling, (0,90,0,90)2s clamped plate (row 1) Nxy,cr [N/mm], Nxy,cr | 288.6 | 295.06 | +2.24 % | Within 10 % |
| Ashton & Love shear buckling, (0,0,0,0)2s clamped plate (row 2) Nxy,cr [N/mm], Nxy,cr | 112.5 | 110.51 | −1.77 % | Within 10 % |
| Ashton & Love shear buckling, (90,45,-45,0)2s clamped plate (row 5) Nxy,cr [N/mm], Nxy,cr | 313 | 311.72 | −0.41 % | Within 10 % |
How to reproduce it
Source
Kosteletos, S., Buckling and Postbuckling of Composite Plates under Shear Load, PhD thesis, University of Glasgow (1990).
Table 3.5, the Ashton & Love tests
What was taken from it
The measured shear buckling load of each plate, as the thesis reprints the Ashton & Love tests.
Quantity compared: Nxy,cr [N/mm]
Inputs
- Boron/epoxy ply, Kosteletos Table 3.5: E1 213.74 GPa, E2 18.616 GPa, G12 5.1711 GPa, ν12 0.28
- Plates 457.2 x 152.4 mm, all edges clamped, positive in-plane shear. Each plate's measured thickness is split evenly over its plies.
The inputs of each configuration are listed in the table below.
Allowed difference
15 %
Compared values, largest error first
| Value | Layup | Reference | Ours | Error |
|---|---|---|---|---|
| Ashton & Love shear buckling, (45,45,45,45)2s clamped plate (row 14) | unidirectional | 121.1 | 92.664 | −23.5 % |
| Ashton & Love shear buckling, (45,45,45,45)2s clamped plate (row 13) | unidirectional | 138.6 | 110 | −20.6 % |
| Ashton & Love shear buckling, (-45,45,-45,45)2s clamped plate (row 8) | angle-ply | 350.3 | 394.9 | +12.7 % |
| Ashton & Love shear buckling, (0,90,0,90)2s clamped plate (row 4) | cross-ply | 241.4 | 265.9 | +10.2 % |
| Ashton & Love shear buckling, (45,-45,45,-45)2s clamped plate (row 7) | angle-ply | 271.4 | 292.31 | +7.70 % |
| Ashton & Love shear buckling, (0,-45,45,90)2s clamped plate (row 10) | quasi-isotropic | 349.4 | 326 | −6.70 % |
| Ashton & Love shear buckling, aluminum clamped plate (row AL02) | isotropic | 288.1 | 306.32 | +6.32 % |
| Ashton & Love shear buckling, (45,-45,45,-45)2s clamped plate (row 11) | angle-ply | 295.3 | 313.18 | +6.06 % |
| Ashton & Love shear buckling, (45,-45,45,-45)2s clamped plate (row 12) | angle-ply | 333.3 | 313.18 | −6.04 % |
| Ashton & Love shear buckling, (0,0,0,0)2s clamped plate (row 3) | unidirectional | 119 | 114.36 | −3.90 % |
| Ashton & Love shear buckling, (90,45,-45,0)2s clamped plate (row 6) | quasi-isotropic | 324 | 311.72 | −3.79 % |
| Ashton & Love shear buckling, (0,-45,45,90)2s clamped plate (row 9) | quasi-isotropic | 325.2 | 337.11 | +3.66 % |
| Ashton & Love shear buckling, aluminum clamped plate (row AL01) | isotropic | 770.9 | 796.3 | +3.30 % |
| Ashton & Love shear buckling, (0,90,0,90)2s clamped plate (row 1) | cross-ply | 288.6 | 295.06 | +2.24 % |
| Ashton & Love shear buckling, (0,0,0,0)2s clamped plate (row 2) | unidirectional | 112.5 | 110.51 | −1.77 % |
| Ashton & Love shear buckling, (90,45,-45,0)2s clamped plate (row 5) | quasi-isotropic | 313 | 311.72 | −0.41 % |
Crawley, E. F., "The Natural Modes of Graphite/Epoxy Cantilever Plates and Shells", J Compos Mater 13(3) (1979) 195-205.
Measured [Hz]
A lab case passes at ±10 % or less. Points outside this band are known gaps, listed below with the reason.
Cases, largest error first
| Case | Reference | Ours | Error | Status |
|---|---|---|---|---|
| Crawley cantilever plate, [0/±45/90]s 76 x 76 mm, mode 2B f [Hz], fWhy: The paper's own finite element analysis is 17.4 % above this test as well. The paper attributes this to in-plane stiffnesses set too high. | 1215 | 1404.6 | +15.6 % | Known gap |
| Crawley cantilever plate, [0/±45/90]s 152 x 76 mm, mode 1B f [Hz], f | 48.6 | 55.21 | +13.6 % | Over 10 % |
| Crawley cantilever plate, [0/±45/90]s 76 x 76 mm, mode 1B f [Hz], f | 196.4 | 222.77 | +13.4 % | Over 10 % |
| Crawley cantilever plate, [0/±45/90]s 152 x 76 mm, mode 2B f [Hz], f | 303 | 343.25 | +13.3 % | Over 10 % |
| Crawley cantilever plate, [±45/∓45]s 76 x 76 mm, mode 1C f [Hz], f | 1168 | 1317.5 | +12.8 % | Over 10 % |
| Crawley cantilever plate, [0₂/±30]s 76 x 76 mm, mode 2B f [Hz], f | 1449 | 1631.5 | +12.6 % | Over 10 % |
| Crawley cantilever plate, [0₂/±30]s 152 x 76 mm, mode 2B f [Hz], f | 362.7 | 405.77 | +11.9 % | Over 10 % |
| Crawley cantilever plate, [0₂/±30]s 152 x 76 mm, mode 1B f [Hz], f | 58.3 | 64.923 | +11.4 % | Over 10 % |
| Crawley cantilever plate, [0₂/±30]s 76 x 76 mm, mode 1B f [Hz], f | 234.2 | 260.24 | +11.1 % | Over 10 % |
| Crawley cantilever plate, [±45/∓45]s 76 x 76 mm, mode 2T f [Hz], f | 1486 | 1637.7 | +10.2 % | Over 10 % |
| Crawley cantilever plate, [0/±45/90]s 76 x 76 mm, mode 2T f [Hz], f | 1550 | 1703.3 | +9.89 % | Within 10 % |
| Crawley cantilever plate, [0/±45/90]s 152 x 76 mm, mode 1C f [Hz], f | 739 | 807.75 | +9.30 % | Within 10 % |
| Crawley cantilever plate, [±45/∓45]s 152 x 76 mm, mode 2T f [Hz], f | 653 | 707.91 | +8.41 % | Within 10 % |
| Crawley cantilever plate, [0₂/±30]s 152 x 76 mm, mode 1T f [Hz], f | 148 | 136.78 | −7.58 % | Within 10 % |
| Crawley cantilever plate, [±45/∓45]s 152 x 76 mm, mode 1T f [Hz], f | 214 | 228.45 | +6.75 % | Within 10 % |
| Crawley cantilever plate, [0/±45/90]s 152 x 76 mm, mode 2T f [Hz], f | 554 | 590.4 | +6.57 % | Within 10 % |
| Crawley cantilever plate, [0₂/±30]s 152 x 76 mm, mode 1C f [Hz], f | 546 | 578.43 | +5.94 % | Within 10 % |
| Crawley cantilever plate, [0₂/±30]s 76 x 76 mm, mode 2C f [Hz], f | 1503 | 1590.7 | +5.84 % | Within 10 % |
| Crawley cantilever plate, [±45/∓45]s 76 x 76 mm, mode 1T f [Hz], f | 472 | 499.39 | +5.80 % | Within 10 % |
| Crawley cantilever plate, [±45/∓45]s 152 x 76 mm, mode 3B f [Hz], f | 533 | 563.73 | +5.77 % | Within 10 % |
| Crawley cantilever plate, [±45/∓45]s 76 x 76 mm, mode 1B f [Hz], f | 131.2 | 138.24 | +5.36 % | Within 10 % |
| Crawley cantilever plate, [0/±45/90]s 76 x 76 mm, mode 1C f [Hz], f | 960 | 1008.1 | +5.01 % | Within 10 % |
| Crawley cantilever plate, [0₂/±30]s 76 x 76 mm, mode 1C f [Hz], f | 728.3 | 755.82 | +3.78 % | Within 10 % |
| Crawley cantilever plate, [0/±45/90]s 152 x 76 mm, mode 1T f [Hz], f | 169 | 174.89 | +3.48 % | Within 10 % |
| Crawley cantilever plate, [±45/∓45]s 152 x 76 mm, mode 2B f [Hz], f | 185.8 | 191.21 | +2.91 % | Within 10 % |
| Crawley cantilever plate, [0₂/±30]s 152 x 76 mm, mode 2T f [Hz], f | 508 | 522.36 | +2.83 % | Within 10 % |
| Crawley cantilever plate, [±45/∓45]s 152 x 76 mm, mode 1B f [Hz], f | 31.3 | 31.933 | +2.02 % | Within 10 % |
| Crawley cantilever plate, [±45/∓45]s 76 x 76 mm, mode 2B f [Hz], f | 790.5 | 798.9 | +1.06 % | Within 10 % |
| Crawley cantilever plate, [0/±45/90]s 76 x 76 mm, mode 1T f [Hz], f | 418 | 420.94 | +0.70 % | Within 10 % |
| Crawley cantilever plate, [0₂/±30]s 76 x 76 mm, mode 1T f [Hz], f | 362 | 361.78 | −0.060 % | Within 10 % |
How to reproduce it
Source
Crawley, E. F., "The Natural Modes of Graphite/Epoxy Cantilever Plates and Shells", J Compos Mater 13(3) (1979) 195-205.
Tables 3 and 4 (observed frequencies); ply properties Appendix B
What was taken from it
The observed frequency of each named mode (bending, torsion, chordwise) of six plates.
Quantity compared: f [Hz]
Inputs
- AS/3501-6 ply, Crawley Appendix B: E1 128 GPa, E2 11 GPa, G12 4.48 GPa, ν12 0.25, 1.5 g/cm³, ply 0.13 mm
- 8 plies, 76 mm wide, 76 or 152 mm long, clamped along one 76 mm edge. Each mode is matched to the paper's by its shape.
The inputs of each configuration are listed in the table below.
Allowed difference
15 %
Compared values, largest error first
| Value | Layup | Reference | Ours | Error |
|---|---|---|---|---|
| Crawley cantilever plate, [0/±45/90]s 76 x 76 mm, mode 2B | quasi-isotropic | 1215 | 1404.6 | +15.6 % |
| Crawley cantilever plate, [0/±45/90]s 152 x 76 mm, mode 1B | quasi-isotropic | 48.6 | 55.21 | +13.6 % |
| Crawley cantilever plate, [0/±45/90]s 76 x 76 mm, mode 1B | quasi-isotropic | 196.4 | 222.77 | +13.4 % |
| Crawley cantilever plate, [0/±45/90]s 152 x 76 mm, mode 2B | quasi-isotropic | 303 | 343.25 | +13.3 % |
| Crawley cantilever plate, [±45/∓45]s 76 x 76 mm, mode 1C | angle-ply | 1168 | 1317.5 | +12.8 % |
| Crawley cantilever plate, [0₂/±30]s 76 x 76 mm, mode 2B | angle-ply | 1449 | 1631.5 | +12.6 % |
| Crawley cantilever plate, [0₂/±30]s 152 x 76 mm, mode 2B | angle-ply | 362.7 | 405.77 | +11.9 % |
| Crawley cantilever plate, [0₂/±30]s 152 x 76 mm, mode 1B | angle-ply | 58.3 | 64.923 | +11.4 % |
| Crawley cantilever plate, [0₂/±30]s 76 x 76 mm, mode 1B | angle-ply | 234.2 | 260.24 | +11.1 % |
| Crawley cantilever plate, [±45/∓45]s 76 x 76 mm, mode 2T | angle-ply | 1486 | 1637.7 | +10.2 % |
| Crawley cantilever plate, [0/±45/90]s 76 x 76 mm, mode 2T | quasi-isotropic | 1550 | 1703.3 | +9.89 % |
| Crawley cantilever plate, [0/±45/90]s 152 x 76 mm, mode 1C | quasi-isotropic | 739 | 807.75 | +9.30 % |
| Crawley cantilever plate, [±45/∓45]s 152 x 76 mm, mode 2T | angle-ply | 653 | 707.91 | +8.41 % |
| Crawley cantilever plate, [0₂/±30]s 152 x 76 mm, mode 1T | angle-ply | 148 | 136.78 | −7.58 % |
| Crawley cantilever plate, [±45/∓45]s 152 x 76 mm, mode 1T | angle-ply | 214 | 228.45 | +6.75 % |
| Crawley cantilever plate, [0/±45/90]s 152 x 76 mm, mode 2T | quasi-isotropic | 554 | 590.4 | +6.57 % |
| Crawley cantilever plate, [0₂/±30]s 152 x 76 mm, mode 1C | angle-ply | 546 | 578.43 | +5.94 % |
| Crawley cantilever plate, [0₂/±30]s 76 x 76 mm, mode 2C | angle-ply | 1503 | 1590.7 | +5.84 % |
| Crawley cantilever plate, [±45/∓45]s 76 x 76 mm, mode 1T | angle-ply | 472 | 499.39 | +5.80 % |
| Crawley cantilever plate, [±45/∓45]s 152 x 76 mm, mode 3B | angle-ply | 533 | 563.73 | +5.77 % |
| Crawley cantilever plate, [±45/∓45]s 76 x 76 mm, mode 1B | angle-ply | 131.2 | 138.24 | +5.36 % |
| Crawley cantilever plate, [0/±45/90]s 76 x 76 mm, mode 1C | quasi-isotropic | 960 | 1008.1 | +5.01 % |
| Crawley cantilever plate, [0₂/±30]s 76 x 76 mm, mode 1C | angle-ply | 728.3 | 755.82 | +3.78 % |
| Crawley cantilever plate, [0/±45/90]s 152 x 76 mm, mode 1T | quasi-isotropic | 169 | 174.89 | +3.48 % |
| Crawley cantilever plate, [±45/∓45]s 152 x 76 mm, mode 2B | angle-ply | 185.8 | 191.21 | +2.91 % |
| Crawley cantilever plate, [0₂/±30]s 152 x 76 mm, mode 2T | angle-ply | 508 | 522.36 | +2.83 % |
| Crawley cantilever plate, [±45/∓45]s 152 x 76 mm, mode 1B | angle-ply | 31.3 | 31.933 | +2.02 % |
| Crawley cantilever plate, [±45/∓45]s 76 x 76 mm, mode 2B | angle-ply | 790.5 | 798.9 | +1.06 % |
| Crawley cantilever plate, [0/±45/90]s 76 x 76 mm, mode 1T | quasi-isotropic | 418 | 420.94 | +0.70 % |
| Crawley cantilever plate, [0₂/±30]s 76 x 76 mm, mode 1T | angle-ply | 362 | 361.78 | −0.060 % |
Nemeth, M. P., "Buckling and Postbuckling Behavior of Square Compression-Loaded Graphite-Epoxy Plates With Circular Cutouts", NASA TP-3007 (1990).
Measured [lb]
A lab case passes at ±10 % or less. Points outside this band are known gaps, listed below with the reason.
Cases, largest error first
| Case | Reference | Ours | Error | Status |
|---|---|---|---|---|
| Nemeth compression buckling, [(±45)₆]s square plate (F1) P_cr [lb], P_cr | 9651 | 11083 | +14.8 % | Over 10 % |
| Nemeth compression buckling, [0₁₀]s square plate (B1) P_cr [lb], P_cr | 9256 | 8533.9 | −7.80 % | Within 10 % |
| Nemeth compression buckling, [(0/90)₅]s square plate (D1) P_cr [lb], P_cr | 6950 | 6548.1 | −5.78 % | Within 10 % |
| Nemeth compression buckling, aluminum square plate (A1) P_cr [lb], P_cr | 1872 | 1951.8 | +4.26 % | Within 10 % |
| Nemeth compression buckling, [90₁₀]s square plate (C1) P_cr [lb], P_cr | 2292 | 2212.6 | −3.47 % | Within 10 % |
| Nemeth compression buckling, [(±30)₆]s square plate (E1) P_cr [lb], P_cr | 10105 | 9863.7 | −2.39 % | Within 10 % |
| Nemeth compression buckling, [(±60)₆]s square plate (G1) P_cr [lb], P_cr | 5790 | 5912.2 | +2.11 % | Within 10 % |
How to reproduce it
Source
Nemeth, M. P., "Buckling and Postbuckling Behavior of Square Compression-Loaded Graphite-Epoxy Plates With Circular Cutouts", NASA TP-3007 (1990).
Tables 1-7, plates without a cutout (d/W = 0); ply properties p. 4
What was taken from it
The measured buckling load of each plate without a cutout.
Quantity compared: P_cr [lb]
Inputs
- AS4/3502 ply, NASA TP-3007 p. 4: E1 18.5e6 psi, E2 1.6e6 psi, G12 0.832e6 psi, ν12 0.35
- Plates 9.5 x 9.5 in, loaded ends clamped, sides simply supported. Each plate's measured thickness is split evenly over its plies.
The inputs of each configuration are listed in the table below.
Allowed difference
15 %
Compared values, largest error first
| Value | Layup | Reference | Ours | Error |
|---|---|---|---|---|
| Nemeth compression buckling, [(±45)₆]s square plate (F1) | angle-ply | 9651 | 11083 | +14.8 % |
| Nemeth compression buckling, [0₁₀]s square plate (B1) | unidirectional | 9256 | 8533.9 | −7.80 % |
| Nemeth compression buckling, [(0/90)₅]s square plate (D1) | cross-ply | 6950 | 6548.1 | −5.78 % |
| Nemeth compression buckling, aluminum square plate (A1) | isotropic | 1872 | 1951.8 | +4.26 % |
| Nemeth compression buckling, [90₁₀]s square plate (C1) | unidirectional | 2292 | 2212.6 | −3.47 % |
| Nemeth compression buckling, [(±30)₆]s square plate (E1) | angle-ply | 10105 | 9863.7 | −2.39 % |
| Nemeth compression buckling, [(±60)₆]s square plate (G1) | angle-ply | 5790 | 5912.2 | +2.11 % |
Leissa, A. W., Vibration of Plates, NASA SP-160 (1969).
Largest error against the reference for each configuration, worst first. The axis is logarithmic: each step up is ten times the error.
4 configurations, largest error first
Cases, largest error first
| Case | Reference | Ours | Error | Status |
|---|---|---|---|---|
| Leissa frequency parameters, isotropic square plate, C-F-F-F λ = ωa²√(ρh/D) [-], λ4 | 27.46 | 27.199 | −0.95 % | Within 1 % |
| Leissa frequency parameters, isotropic square plate, C-C-C-C λ = ωa²√(ρh/D) [-], λ5 | 131.64 | 131.58 | −0.045 % | Within 1 % |
| Leissa frequency parameters, isotropic square plate, SS-C-SS-C λ = ωa²√(ρh/D) [-], λ1 | 28.946 | 28.951 | +0.017 % | Within 1 % |
| Navier frequencies, isotropic square plate ω [rad/s], ω6 | 1689.7 | 1689.7 | <0.001 % | Within 1 % |
How to reproduce it
Source
Leissa, A. W., Vibration of Plates, NASA SP-160 (1969).
Tables 4.3, 4.22, 4.45 and Eq. 4.20
What was taken from it
The tabulated frequency parameters, and the closed-form simply supported frequencies.
Quantity compared: λ = ωa²√(ρh/D) [-]; ω [rad/s]
Inputs
The inputs of each configuration are listed in the table below.
Allowed difference
upper bound: +0.005 above, 1.5 % below; 0.1 %; 0.05 %; 0.001 %
Compared values, largest error first
| Value | Layup | Reference | Ours | Error |
|---|---|---|---|---|
| Leissa frequency parameters, isotropic square plate, C-F-F-F, λ4 | isotropic | 27.46 | 27.199 | −0.95 % |
| Leissa frequency parameters, isotropic square plate, C-F-F-F, λ3 | isotropic | 21.44 | 21.288 | −0.71 % |
| Leissa frequency parameters, isotropic square plate, C-F-F-F, λ5 | isotropic | 31.17 | 30.96 | −0.67 % |
| Leissa frequency parameters, isotropic square plate, C-F-F-F, λ1 | isotropic | 3.494 | 3.4713 | −0.65 % |
| Leissa frequency parameters, isotropic square plate, C-F-F-F, λ2 | isotropic | 8.547 | 8.5077 | −0.46 % |
| Leissa frequency parameters, isotropic square plate, C-C-C-C, λ5 | isotropic | 131.64 | 131.58 | −0.045 % |
| Leissa frequency parameters, isotropic square plate, C-C-C-C, λ6 | isotropic | 132.18 | 132.2 | +0.019 % |
| Leissa frequency parameters, isotropic square plate, SS-C-SS-C, λ1 | isotropic | 28.946 | 28.951 | +0.017 % |
| Leissa frequency parameters, isotropic square plate, SS-C-SS-C, λ3 | isotropic | 69.32 | 69.327 | +0.010 % |
| Leissa frequency parameters, isotropic square plate, C-C-C-C, λ2 | isotropic | 73.4 | 73.394 | −0.0084 % |
| Leissa frequency parameters, isotropic square plate, C-C-C-C, λ3 | isotropic | 73.4 | 73.394 | −0.0084 % |
| Leissa frequency parameters, isotropic square plate, SS-C-SS-C, λ6 | isotropic | 129.09 | 129.1 | +0.0074 % |
| Leissa frequency parameters, isotropic square plate, C-C-C-C, λ1 | isotropic | 35.987 | 35.985 | −0.0039 % |
| Leissa frequency parameters, isotropic square plate, SS-C-SS-C, λ5 | isotropic | 102.21 | 102.22 | +0.0032 % |
| Leissa frequency parameters, isotropic square plate, C-C-C-C, λ4 | isotropic | 108.22 | 108.22 | −0.0032 % |
| Leissa frequency parameters, isotropic square plate, SS-C-SS-C, λ4 | isotropic | 94.584 | 94.585 | +0.0014 % |
| Leissa frequency parameters, isotropic square plate, SS-C-SS-C, λ2 | isotropic | 54.743 | 54.743 | <0.001 % |
| Navier frequencies, isotropic square plate, ω6 | isotropic | 1689.7 | 1689.7 | <0.001 % |
| Navier frequencies, isotropic square plate, ω5 | isotropic | 1689.7 | 1689.7 | <0.001 % |
| Navier frequencies, isotropic square plate, ω3 | isotropic | 844.86 | 844.86 | <0.001 % |
| Navier frequencies, isotropic square plate, ω2 | isotropic | 844.86 | 844.86 | <0.001 % |
| Navier frequencies, isotropic square plate, ω4 | isotropic | 1351.8 | 1351.8 | <0.001 % |
| Navier frequencies, isotropic square plate, ω1 | isotropic | 337.94 | 337.94 | <0.001 % |
Zenkert, D., An Introduction to Sandwich Construction, EMAS (1995).
Largest error against the reference for each configuration, worst first. The axis is logarithmic: each step up is ten times the error.
2 configurations, largest error first
Cases, largest error first
| Case | Reference | Ours | Error | Status |
|---|---|---|---|---|
| Sandwich core shear at q·b/2 τ [MPa], τy | 0.035714 | 0.035714 | <0.001 % | Within 1 % |
| Sandwich face wrinkling allowable, plate σ_wr [MPa], σ_wr | 326.6 | 326.6 | <0.001 % | Within 1 % |
How to reproduce it
Source
Zenkert, D., An Introduction to Sandwich Construction, EMAS (1995).
Eq. 3.30 and the core shear τ = q·b/(2d)
What was taken from it
The closed-form expressions, evaluated for one panel.
Quantity compared: τ [MPa]; σ_wr [MPa]
Inputs
The inputs of each configuration are listed in the table below.
Allowed difference
0.1 %; 0.5 %
Compared values, largest error first
| Value | Layup | Reference | Ours | Error |
|---|---|---|---|---|
| Sandwich core shear at q·b/2, τy | sandwich | 0.035714 | 0.035714 | <0.001 % |
| Sandwich face wrinkling allowable, plate, σ_wr | sandwich | 326.6 | 326.6 | <0.001 % |
The tick on each bar marks the limit for that group. A bar past the tick is over the limit.
How the numbers are checked
The two groups answer two different questions. Reference solutions check that the program solves its equations correctly: the same model, solved by someone else in a published solution, an independent implementation or a finite element model, gives the same number. Engineers call this verification. Lab tests check that the equations describe a real part, which no amount of matching other programs can show. That is validation. A method can pass every verification case and still differ from a test, because the model leaves something out. The terms follow NAFEMS, What is Verification and Validation? (2014).
A reference case counts as within when its error is at most 1 %, a lab case when it is at most 10 %. A known gap is a case where the method and the reference disagree for a reason that is understood. It stays on this page with its reason until the method changes.