Ply Stresses in a [±45]s Laminate under Tension
Pull a ±45 laminate along x and each ply ends up in shear. Worked from the A matrix to the safety factor.
Problem
A [45/−45]s laminate of T300/5208 carbon/epoxy carries Nx = 100 N/mm of tension, with no other load. Find the stresses in each ply along and across its fibers, and the Tsai-Wu safety factor.
Ply 1 on top: 45°, −45°, −45°, 45°, 0.125 mm each, 0.5 mm in total. Angles run counterclockwise from x.
Inputs
| Layup | [45/−45]s, ply 1 on top |
| Ply thickness | 0.125 mm |
| E1 | 181000 MPa |
| E2 | 10300 MPa |
| G12 | 7170 MPa |
| ν12 | 0.28 |
| S1t / S1c | 1500 / 1500 MPa |
| S2t / S2c | 40 / 246 MPa |
| S12 | 68 MPa |
| Nx | 100 N/mm |
| Ny, Nxy, M | 0 |
Change the ply angle
Same material, same Nx, any angle from 0 to 90°. The curves show the +θ ply; the −θ ply has the same σ1 and σ2 and the opposite τ12.
[45/−45]s under Nx = 100 N/mm
| Ply | σ1 | σ2 | τ12 | SF |
|---|---|---|---|---|
| +45° | 186.6 | 13.38 | −100 | 0.6161 |
| −45° | 186.6 | 13.38 | 100 | 0.6161 |
Stresses in MPa, in the fiber axes of each ply.
At θ = 45° the +θ ply carries σ1 = 187, σ2 = 13.4 and τ12 = −100 MPa. Tsai-Wu says the plies fail before 100 N/mm, at about 61.6 N/mm.
σ1 + σ2 stays at 200 MPa at every angle, which is Nx spread over the 0.5 mm thickness. The angle only decides how that stress splits between the fiber and the matrix, and how much shear comes with it.
Results
The shear stress in the fiber axes is the same size in every ply, 100 MPa, and it fails the laminate before the 100 N/mm load is reached.
Step 1. The A matrix
Rotate each ply's stiffness Q into the laminate axes (Q̄) and sum over the plies, weighted by thickness. The stack is symmetric, so B = 0, and balanced, so A16 = A26 = 0. In N/mm:
Step 2. Midplane strains
With B = 0 the membrane problem stands alone. Solve A ε0 = N:
There is no curvature, so every ply sees these same strains. The laminate narrows by 0.747 times its stretch: that ratio is νxy, and it is large because the ±45 plies scissor.
Step 3. Rotate into the fiber axes
For the +45° ply, with c = cos θ and s = sin θ:
At 45° the fiber and transverse strains are equal, and the shear strain is the difference of εx and εy. In the −45° ply γ12 flips sign.
Step 4. Ply stresses
Multiply by the ply stiffness in its own axes, Q11 = 181811, Q12 = 2896.92, Q22 = 10346.2 and Q66 = 7170 MPa:
Step 5. Tsai-Wu safety factor
Scale the stresses by SF until the Tsai-Wu index reaches 1. The linear terms L = F1σ1 + F2σ2 grow with SF, the quadratic terms Q with SF2:
All four plies, stresses in MPa:
| Plies | Angle | ε1 (µε) | ε2 (µε) | γ12 (µε) | σ1 | σ2 | τ12 | Tsai-Wu SF |
|---|---|---|---|---|---|---|---|---|
| 1, 4 | 45° | 1010 | 1010 | −13950 | 186.6 | 13.38 | −100 | 0.6161 |
| 2, 3 | −45° | 1010 | 1010 | 13950 | 186.6 | 13.38 | 100 | 0.6161 |
What it means
Under axial load a ±45 laminate works through its matrix. At 45° the fibers carry σ1 = 186.6 MPa, about 12% of their strength. The shear, 100 MPa against S12 = 68 MPa, is what fails the ply.
Move θ toward 0° and the fibers line up with the load: shear drops away and the safety factor climbs to 7.5. Move it toward 90° and σ2 takes over, against a transverse tensile strength of only 40 MPa, so the safety factor falls to 0.2. Use ±45 plies for shear and torsion stiffness, and 0° plies for the axial load.
First-ply failure is where matrix cracking starts, not where the laminate breaks. Past it the cracked plies lose transverse and shear stiffness and the load moves to the fibers.
Related docs:
References
- Jones, R.M., Mechanics of Composite Materials, 2nd Ed., Taylor & Francis, 1999.