ABD Composites

Bonded Single Lap vs Published Tests

A strain gauge beside the overlap of a carbon/epoxy single lap, read at six loads, against the tool and a finite-element model.

Problem

A single lap bends as it is loaded, because the two plates pull along lines one plate thickness apart. Comer and co-workers put a strain gauge on the outer face of one adherend, just outside the overlap, and recorded its axial strain as they pulled a pre-preg single lap apart1. At low load the bending wins and the gauge reads compression. As the joint rotates into line, the tension takes over. How close does the Bonded Joint tool get to that strain?

PPg = 9.6 mmGaugeL = 25.4 mmAdhesive

Not to scale. The gauge sits on the free face of the upper adherend.

Inputs

AdherendsHTA/6376, (0/90)4s
E1, E2, G12140000, 10000, 5200 MPa
ν12, ply thickness0.3, 0.13 mm
AdhesiveEpoxy paste, 0.2 mm
Overlap L, width25.4, 25.4 mm
Gauge, past the overlap end9.6 mm
Load inputFree arms, long
Adhesive modulus3050 to 4440 MPa

The geometry is from Comer's Fig. 11. The paper does not give ply properties, so they are taken from Gray and McCarthy's Table 1 for the same HTA/63762, at 0.13 mm per ply. Sixteen plies make 2.08 mm, against Comer's nominal 2 mm.

The adhesive is a two-part research-grade epoxy paste, and the paper gives none of its properties. So its modulus is bracketed by the lowest and highest epoxy in da Silva and co-workers' comparison, 3050 and 4440 MPa3. For the tool that bracket makes no difference here. The paper gives no grip length either, so the tool runs the free arms as long, and in that mode the end moment comes from treating the overlap as rigid. The adhesive then moves the shear and peel in the bond but not the moment in the arm, and the gauge strain comes out the same for both moduli. The finite-element model does see the adhesive, so it is shown as a band between the two.

Predicted against test

The gauge readings were read off Comer's Fig. 8 at six loads, to about ±15 µε. The tool's strain is the top-face strain at the gauge position, from the axial force and bending moment the tool gives along the arm. The finite-element model is a geometrically nonlinear plane-strain model of the same joint, with each arm 160 mm long, so it too behaves as a long arm.

02468−3000300600900Joint load (kN)Gauge strain (µε)
Strain gauge, test Tool Finite element, adhesive range

In words: all three start in compression and rise with load. The measured strain sits above both predictions at every load, and the tool falls further behind as the load grows.

Results

Tool against gauge
−303 to −97 µε
over six loads
Largest miss, at 8.00 kN
303 µε below the gauge
unconservative
Finite-element model against gauge
−175 to −67 µε
both adhesive moduli

Strain in µε at the gauge. The tool's difference from the gauge is in brackets, and the band is ±150 µε, a tenth of Fig. 8's full scale. A row outside it is marked.

Load (kN)GaugeToolFinite element
1.70-110-207 (−97)-191 to -190
3.66-4-127 (−123)-78 to -76
5.001506 (−144)80 to 83
6.00330131 (−199), unconservative224 to 227
7.00535274 (−261), unconservative384 to 389
8.00732429 (−303), unconservative557 to 563

Source: Comer et al. Fig. 8, the pre-preg joint's strain gauge, digitized1. The finite-element range runs from the 3050 to the 4440 MPa adhesive.

What it means

The tool reads below the gauge at every load, and the gap grows with load: 97 µε at 1.70 kN, 303 µε at 8.00 kN. From 6.00 kN up it is outside the ±150 µε band, on the unconservative side for this face. The finite-element model reads low too, by 169 to 175 µε at 8.00 kN. Part of the gap is likely in what this page had to assume: ply properties from another paper and an arm length the paper does not give.

The rest belongs to the tool. At 1.70 kN it sits 16 to 17 µε under the finite-element model, and at 8.00 kN 128 to 134 µε. The load fixes the axial force in the arm, so a free-face strain that reads low means the tool carries more bending moment than the joint did. The bonded face sees that moment with the opposite sign, so there the tool's strain reads high by the same amount. The adherend check looks at every ply through the thickness and keeps the worst, so on this joint it errs on the safe side. Read the free-face strain as low once the joint has rotated into line.

Related docs:

References

  1. Comer, A.J., Katnam, K.B., Stanley, W.F. & Young, T.M. (2013). Characterising the behaviour of composite single lap bonded joints using digital image correlation. International Journal of Adhesion and Adhesives, 40, 215-223. doi:10.1016/j.ijadhadh.2012.08.010 (Fig. 1, joint geometry; Fig. 8, strain gauge reading against load)
  2. Gray, P.J. & McCarthy, C.T. (2010). A global bolted joint model for finite element analysis of load distributions in multi-bolt composite joints. Composites Part B: Engineering, 41, 317-325. doi:10.1016/j.compositesb.2010.03.001 (Table 1, HTA/6376 ply properties)
  3. da Silva, L.F.M., das Neves, P.J.C., Adams, R.D., Wang, A. & Spelt, J.K. (2009). Analytical models of adhesively bonded joints, Part II: Comparative study. International Journal of Adhesion and Adhesives, 29(3), 331-341. doi:10.1016/j.ijadhadh.2008.06.007 (Table 2, adhesive properties)
Written by Rick Schrijver